We are now unveiling our new power supply that incorporates features meant to make your job easier. With a status display, bus monitoring, and test points right on the faceplate we made this design with the end user in mind. We are bringing to you a supply that was built to provide many years of continuous service for your application. We can provide more info if you call us at 281-421-1321 or email [email protected].
Input Voltage:
AC (50 hertz to 500 hertz) or DC, With Automatic Voltage Selection
100 Volt AC or DC Min
200 Volt AC or DC Max
120 - 150 Volt AC or DC Nominal
78% - 88% Efficiency
.2% Voltage Difference Between No Load and Full Load
Hold-up Capacitor:
2200uF @ 250 Volts (100uF @ 250 Volts OEM)
Temperature Range:
-10 degrees C to +100 degrees C (per brick at full load)
Output:
All Fused
+15/-15 Volts Fused At 5 Amps,
5 Volts Fused At 9 Amps
But Actual Capabilities 5V @ 20A, 15V @ 10A and -15V @ 10A
Outputs Wired For Redundant Operation
Voltage Adjustment Located On Front Panel
Voltage Test Points On Front Panel (Before O-ring Diode)
Alarming:
Alarm When Input Voltage Out Of Range or Failure
Alarm When Output Voltage Out Of Range or Failure
Audible Alarm (Horn) And Flashing Red LED On Input Or Output
Failure
Green LED For Input And Output Normal Operation
Test Switch To Test Alarm Circuitry (Horn And Flashing Red
LED)
Output Display:
Output Display Size - 75.0(W)mm X
52.7(H)mm X MAX9.5(D)mm (LED B/L) LCD Back Light
Displays Voltage / Current / Status